Industry Security Combustible Gas Toxic Gas Detector Instruction And Troubleshooting

2025-10-15 20:21:09
Industry Security Combustible Gas Toxic Gas Detector Instruction And Troubleshooting

1. FAQ for Explosion Proof Gas Detector

Can combustible gas detectors detect all combustible gases?

Yes.

How long can a combustible gas detector be used to monitor the minimum value of gas explosion and detect the comprehensive concentration of all combustible gases?

Under normal circumstances, it can be used for 3-5 years.

If the on-site environment is harsh, it will shorten the service life and require replacement within 1-2 years.

Can combustible gas detectors be linked to draught fan?

sure. It can not only drive draught fan, but also drive external devices such as solenoid valves and alarm lights.

Can combustible gas detectors and toxic gas detectors share the same host?

Yes.

What does the host do? Do I have to use it in combination?

The host can provide power to the detector, display real-time on-site concentration, and link with external devices. The host is installed in the central control room and duty room, so even if you are not on site, you can receive timely alarm notifications and handle the alarm situation in a timely manner.

Can the YA-D300 gas detector be used alone?

It can be used independently, powered by a 24V power supply, or alternatively powered by a 90-240V AC power supply.

Do I need to set the alarm value of the gas alarm myself?

It’s not necessary. The products are set up according to international standards before shipment. After receiving the goods, wiring and use it directly.

YA-D300-CO-gas-detector.jpeg.jpg

What materials are required for installation?

Strict explosion-proof places should prepare signal shielding wires and use galvanized pipes or steel pipe explosion-proof junction boxes for wiring.

How often is the gas detector calibrated?

Normally, it should be calibrated once a year.

YA-D300_副本.jpg

Tags: industry gas detector, industry security gas sensor, H2S gas alarm